Weather station manufacturer contact number+86 15898932201

Product Center

Water Quality Monitor System

Water Quality Monitor System

【Product introduction】Water Quality Monitor System can monitor PH, temperature, turbidity, conductivity, dissolved oxygen, COD, ammonia nitrogen and other water quality parameters.

Model:FT-QSZ1

Brand:fengtu

Product details

1. Water Quality Monitor System product introduction

1.Overview

Water Quality Monitor System can monitor PH, temperature, turbidity, conductivity, dissolved oxygen, COD, ammonia nitrogen and other water quality parameters.QSZ1Water Quality Monitor System is a comprehensive sensor collection, display, and analysis system based on Internet of Things technology.It is a water supply water quality monitoring microsystem.It is composed of a steady flow exhaust unit, an analysis and test unit, a system control unit, and a remote communication unit.It has a complete power supply , lightning protection, network communication and other functions.

2.Product positioning

QSZ1Water Quality Monitor System has an automatic monitoring function.The main monitoring items of the integrated extraction micro water quality automatic monitoring station are: PH, temperature, turbidity, conductivity, dissolved oxygen, COD, ammonia nitrogen, suspended solids, total nitrogen, etc.It uses highly integrated technology to implement automatic water quality monitoring functions in a cabinet.

The Water Quality Monitor System can be widely used for online monitoring of water quality in rivers, urban or village water plants, tap water pipeline networks, secondary tap water supply, user terminals, indoor swimming pools, large water purification equipment and direct drinking water.It is an important part of the water plant production process.Indispensable online analysis equipment in fields such as control, water conservancy and water management, and health supervision.

3.Functions and features

GPRS networking 4G

Support extended RJ45 networking

Support extended sensor remote transmission

Support LED screen display 7.0-inch touch control screen

Support expanding Android screen display and storage

Extended Android screen supports 2G data storage and U disk data export

Supports one RS485 modbus-RTU protocol slave station

Supports multi-channel RS485 modbus-RTU sensor expansion

Supporting IoT data display, storage and analysis platform

The platform supports data forwarding of multiple protocols such as TCP short link and HTTP protocol.

2.Water Quality Monitor System system composition

The water supply quality monitoring microsystem consists of a power supply unit, a water pump control unit, an analysis and testing unit, a display unit, a water pump unit, a remote communication unit and an integrated box main unit.

1.Power supply unit

Power supply AC220V.

2.Water pump control unit

Intelligent self-priming pump maximum lift: 25m opening flow: 1.8m3/h

3.Analyze the test unit

The analytical test unit is mainly composed of pH, dissolved oxygen, conductivity, turbidity, ORP, and temperature sensors, which are fixed on the flow cell through threads or tight-fitting fixtures.The main parameters of the sensor are as follows:

Model Name Measurement range Principle Measurement accuracy Resolution Is it standard equipment Note
S1S cod 0~1000mg/L UV254 absorption method ±5%, ±0.3℃ 0.1mg/L cod turbidity integrated; brush self-cleaning, with temperature compensation
Turbidity 0~400NTU Scattering light method ±1%, ±0.3℃ 0.1NTU
S2 Water hardness 0~1000.0mg/L Contact method of electrode Reading ±10%; ±0.3℃ 0.1mg/L
S3 pH 0~14 (ph) Electrochemistry (salt bridge) ±0.1PH;±0.1℃ 0.01 With warm supplement
pH 0~14 (ph) Electrochemistry (salt bridge) ±0.1PH;±0.1℃ 0.01
S5 Ammonium nitrogen 0~1000mg/l Ion selective electrode method 10% of the reading, ±0.5℃ 0.01mg Ammonia nitrogen pH integrated; with temperature compensation
pH 0~14 (ph) Electrochemistry (salt bridge) ±0.1PH;±0.1℃ 0.01
S6 ORP -1500mv~1500mv Electrochemistry (salt bridge) ±6mv 1mV
S7 Electrical conductivity 0~10000uS/cm Contact method of electrode ±1.5%; ±0.1°C 1uS/cm With warm supplement
S7H High range conductivity 0~30000μS/cm Contact method of electrode ±1.5%; ±0.1°C 1uS/cm High range conductivity TDS salinity sensor; with temperature compensation
TDS 0-10000ppm Contact method of electrode ±1.5%; ±0.1°C 1ppm
Salinity 0-10000ppm Contact method of electrode ±1.5%; ±0.1°C 1ppm
S8 Dissolved oxygen 0~20mg/L Fluorescence lifetime method ±2%, ±0.3℃ 0.01mg/L With warm supplement
S9 Turbidity 0~1000NTU Scattering light method ±1%, ±0.3℃ 0.1NTU With warm supplement
S10 Suspended matter 0~2000mg/L Scattering light method ±5% (depending on the homogeneity of the sludge) 0.1mg/L
S11S Sludge concentration 0~20.000g/L Scattering light method ±5% (depending on the homogeneity of the sludge) 0.001g/L Brushed self-cleaning
S15S Chlorophyll 0~400ug/L Fluorescence method R²>0.999 0.01ug/L Self-cleaning with brush; with temperature compensation
S16S Cyanobacteria 0~200.0Kcells/mL Fluorescence method R²>0.999 0.1Kcells/mL Brushed self-cleaning
S17S Oil in water 0~60ppm Fluorescence method 0.1ppm 0.01ppm Brushed self-cleaning
S20 Transparency 50~1000mm Scattering light method ±5% (depending on the homogeneity of the sludge) 1mm With warm supplement
S21 Water temperature −20℃~85℃ High-precision digital sensor ±0.1℃ 0.1℃

Note: The sensor cannot be installed upside down or horizontally.It must be installed at an angle of at least 15 degrees.The working environment of the above water quality sensor is 0-50℃, <0.3Mpa.

4.Display unit

Multi-parameter monitor, installed at the cabinet door, performs data collection, analysis, display, communication, and data storage operations.

Android version: 4.4.2·CPU: Quad-core Cortex™-A7·RAM/ROM: 512M/4G·Screen: 7-inch capacitive touch screen·Power supply: 12V/1A·Supports U disk expansion and memory card expansion

5.Remote communication

RS485 interface MODBUS-RTU communication protocol Factory device address 6 decimal supports 03 function code to read data

6.Equipment box main unit

Installation method The cabinet floor is installed on the base.
Overall dimensions 1684mm*560mm*510mm 50-100mm adjustable
Shell material 216 stainless steel.
Protection level IP54
powered by Mains power AC220V
water inlet 4 points PE pipe
water outlet 6 points water purifier PE pipe
sewage outlet 4-point water purifier hose, (can also be manually drained regularly)
Self-priming pump Motor power: 200W
Rated voltage:AC220V/50hz
Water pump size 210*145*245/mm
Maximum suction lift: 8m; Maximum lift: 25m
Opening flow: 1.8m3/h


Article address:https://www.sqqx.net/en/Source-Water-Monitor/Water-Quality-Monitor-System.html