【Product introduction】Drinking water monitoring system should be installed at the water inlet and the water outlet of the water plant, with enough space and easy operation.

Model:FT-YYS05

Brand:fengtu

Product details

1. Drinking water monitoring system product introduction

Drinking water monitoring system should be installed at the water inlet and the water outlet of the water plant, with enough space and easy operation.YYS05 online drinking water monitoring system is an instrument that can monitor water temperature, ph, residual chlorine, turbidity and conductivity online.It integrates corresponding sensors and measurement module communication storage, and can quickly and accurately record key parameters in the water body.At the same time, the instrument supports extended water quality multi-parameter sensors, including but not limited to pH, dissolved oxygen (DO), conductivity, turbidity, temperature, ammonia nitrogen, etc., which can be combined and configured according to different needs and applications, and record and store history Monitoring data and alarm history records support historical data export.xlsx.The RS485 interface supports the MODBUS-RTU communication protocol to facilitate users to freely communicate with PLC, DCS, configuration software, DTU and other equipment to connect and transmit data.

2.Application fields of Drinking water monitoring system

Online Drinking water monitoring system is widely used in the monitoring and control of various water bodies, including but not limited to the following fields:

1.Water plant: used to monitor the pH value, dissolved oxygen, turbidity and other parameters of tap water to ensure the safety and hygiene of tap water.

2.Groundwater monitoring: used to monitor the pH value, conductivity, temperature and other parameters of groundwater to detect and solve water quality problems in a timely manner.

3.River and lake monitoring: used to monitor the water quality conditions of rivers and lakes, such as dissolved oxygen, turbidity, ammonia nitrogen and other parameters, so as to take timely pollution control measures.

4.Marine monitoring: used to monitor the water quality conditions of the ocean, such as salinity, dissolved oxygen, temperature and other parameters, so as to detect and control marine pollution in a timely manner.

5.Sewage treatment: used to monitor the water quality parameters of sewage, such as pH value, COD, ammonia nitrogen, etc., in order to control and adjust the sewage treatment process.

6.Industrial production: used to monitor water quality conditions during industrial production, such as pH, conductivity, dissolved oxygen and other parameters, so as to adjust the process in a timely manner and ensure product quality.

7.Scientific research: used for water quality monitoring in the field of scientific research, such as lake eutrophication, climate change, etc.

3.Technical characteristics of Drinking water monitoring system

1.High reliability: suitable for long-term work in outdoor environments, with stable measurement and strong anti-interference ability.

2.Flexible and portable: Each probe can be freely combined, replaced independently, plug and play.

3.Scalability: A variety of sensors can be freely combined.

4.Various applications: on-site rapid measurement, emergency monitoring, or long-term online monitoring of groundwater, river water, lake water sources, and urban pipe network water.

5.Tough shell: ABS+PC material, anti-corrosion, can work continuously and normally for a long time.

6.Compact structure: can be installed in smaller places.

7.Communication connection: RS485 expansion interface, the master/slave interface is isolated and can communicate independently.

4.Technical parameters of Drinking water monitoring system

show output4.3-inch touch screen with strong LED backlight, can be operated under direct sunlight
power supplyDC power supply: DC12V
Power consumptionThe power consumption of the instrument is about 12V/1W
sound outputbuzzer
Communication protocolStandard RS485 Modbus-RTU protocol and device master/slave transmission channel support
Main materialsABS+PC material
Storage temperature-20 to 70℃
operating temperature-10 to 50℃
Protection levelIP65
size175mm*140mm*49mm(length×width×height)
weightAbout 0.5KG

5.Drinking water monitoring system sensor configuration (optional)

serial numbernameMeasuring rangeprincipleMeasurement accuracyConfigurationRemark
1temperature0~50℃High-precision digital sensor±0.3℃
2pH0~14(ph)Electrochemistry (Salt Bridge)±0.1PH
3ORP-1500mv~1500mvElectrochemistry (Salt Bridge)±6mv

4Conductivity0~5000uS/cmcontact electrode method±1.5%
5Turbidity0~40NTU (low turbidity)scattered light method±1%Optional
0~1000NTU (medium turbidity)scattered light method±1%
0~3000NTU (high turbidity)scattered light method±1%
6Dissolved oxygen0~20mg/Lfluorescence lifetime method±2%

7Ammonia nitrogen0~100mg/lIon selective electrode method±1mg

8suspended solids0~2000mg/Lscattered light method±5% (depending on sludge homogeneity)

9Residual chlorine0~5.00 mg/LIon selective electrode method±5% of reading
10Chloride ion0-3500.0mg/LIon selective electrode method±5%

11Total hardness0~1000.0mg/LIon selective electrode method±10% of reading

12cod0~500mg/LUV254 absorption method±5%
COD and chlorophyll are equipped with automatic cleaners to prevent biological adhesion and avoid light window pollution to ensure long-term monitoring is still stable; the automatic cleaning time and cleaning frequency can be set, and the power consumption is 0.7W
13Chlorophyll0~400ug/LFluorescence methodR2>0.999